🚚 Free Worldwide Shipping on All Orders!Shop Now
HLA-ABC Monoclonal Antibody (W6/32), PerCP-eFluor 710, eBioscience
HomeStore

HLA-ABC Monoclonal Antibody (W6/32), PerCP-eFluor 710, eBioscience

HLA-ABC Monoclonal Antibody (W6/32), PerCP-eFluor 710, eBioscience

PRODUCT DETAILS

Host: Mouse

Isotype: IgG2a, kappa

Clonality: Monoclonal

Clone: W6/32

Format: PerCP-eFluor 710

Reactivity: Hu

Application: Flow Cytometry

Tested Dilution: 5 µL (0.25 µg)/test

Concentration: 5 μL/Test

Storage: 4°C, store in dark, DO NOT FREEZE!

Formulation: PBS with BSA and 0.09% sodium azide; pH 7.2

Purification: Affinity chromatography

Data Sheet: TDS


Specific Information

Description: The W6/32 monoclonal antibody reacts with the human major histocompatibility complex (MHC) class I, HLA-A, B, C. MHC class I antigens associated with beta 2-microglobulin are expressed by all human nucleated cells and are central in cell-mediated immune response and tumor surveillance. W6/32 mAb recognizes a non-polymorphic epitope shared among products of the HLA-A, B, and C loci and immunoprecipitates both 43 kDa and 11-12 kDa chains. Crossreactivity is also seen in baboon, rhesus and cynomolgus monkey.

Applications Reported: This W6/32 antibody has been reported for use in flow cytometric analysis.

Applications Tested: This W6/32 antibody has been pre-titrated and tested by flow cytometric analysis of normal human peripheral blood cells. This can be used at 5 µL (0.25 µg) per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test.

PerCP-eFluorâ„¢ 710 can be used in place of PE-Cy5, PE-Cy5.5 or PerCP-Cy5.5. PerCP-eFluorâ„¢ 710 emits at 710 nm and is excited with the blue laser (488 nm). Please make sure that your instrument is capable of detecting this fluorochrome. For a filter configuration, we recommend using the 685 LP dichroic mirror and 710/40 band pass filter, however the 695/40 band pass filter is an acceptable alternative.

Our testing indicates that PerCP-eFluor™ 710 conjugated antibodies are stable when stained samples are exposed to freshly prepared 2% formaldehyde overnight at 4°C, but please evaluate for alternative fixation protocols.

Excitation: 488 nm; Emission: 710 nm; Laser: Blue Laser.

Filtration: 0.2 µm post-manufacturing filtered.

 

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
$137.40

Original: $458.00

-70%
HLA-ABC Monoclonal Antibody (W6/32), PerCP-eFluor 710, eBioscience—

$458.00

$137.40

HLA-ABC Monoclonal Antibody (W6/32), PerCP-eFluor 710, eBioscience

PRODUCT DETAILS

Host: Mouse

Isotype: IgG2a, kappa

Clonality: Monoclonal

Clone: W6/32

Format: PerCP-eFluor 710

Reactivity: Hu

Application: Flow Cytometry

Tested Dilution: 5 µL (0.25 µg)/test

Concentration: 5 μL/Test

Storage: 4°C, store in dark, DO NOT FREEZE!

Formulation: PBS with BSA and 0.09% sodium azide; pH 7.2

Purification: Affinity chromatography

Data Sheet: TDS


Specific Information

Description: The W6/32 monoclonal antibody reacts with the human major histocompatibility complex (MHC) class I, HLA-A, B, C. MHC class I antigens associated with beta 2-microglobulin are expressed by all human nucleated cells and are central in cell-mediated immune response and tumor surveillance. W6/32 mAb recognizes a non-polymorphic epitope shared among products of the HLA-A, B, and C loci and immunoprecipitates both 43 kDa and 11-12 kDa chains. Crossreactivity is also seen in baboon, rhesus and cynomolgus monkey.

Applications Reported: This W6/32 antibody has been reported for use in flow cytometric analysis.

Applications Tested: This W6/32 antibody has been pre-titrated and tested by flow cytometric analysis of normal human peripheral blood cells. This can be used at 5 µL (0.25 µg) per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test.

PerCP-eFluorâ„¢ 710 can be used in place of PE-Cy5, PE-Cy5.5 or PerCP-Cy5.5. PerCP-eFluorâ„¢ 710 emits at 710 nm and is excited with the blue laser (488 nm). Please make sure that your instrument is capable of detecting this fluorochrome. For a filter configuration, we recommend using the 685 LP dichroic mirror and 710/40 band pass filter, however the 695/40 band pass filter is an acceptable alternative.

Our testing indicates that PerCP-eFluor™ 710 conjugated antibodies are stable when stained samples are exposed to freshly prepared 2% formaldehyde overnight at 4°C, but please evaluate for alternative fixation protocols.

Excitation: 488 nm; Emission: 710 nm; Laser: Blue Laser.

Filtration: 0.2 µm post-manufacturing filtered.

 

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.

Product Information

Shipping & Returns

Description

PRODUCT DETAILS

Host: Mouse

Isotype: IgG2a, kappa

Clonality: Monoclonal

Clone: W6/32

Format: PerCP-eFluor 710

Reactivity: Hu

Application: Flow Cytometry

Tested Dilution: 5 µL (0.25 µg)/test

Concentration: 5 μL/Test

Storage: 4°C, store in dark, DO NOT FREEZE!

Formulation: PBS with BSA and 0.09% sodium azide; pH 7.2

Purification: Affinity chromatography

Data Sheet: TDS


Specific Information

Description: The W6/32 monoclonal antibody reacts with the human major histocompatibility complex (MHC) class I, HLA-A, B, C. MHC class I antigens associated with beta 2-microglobulin are expressed by all human nucleated cells and are central in cell-mediated immune response and tumor surveillance. W6/32 mAb recognizes a non-polymorphic epitope shared among products of the HLA-A, B, and C loci and immunoprecipitates both 43 kDa and 11-12 kDa chains. Crossreactivity is also seen in baboon, rhesus and cynomolgus monkey.

Applications Reported: This W6/32 antibody has been reported for use in flow cytometric analysis.

Applications Tested: This W6/32 antibody has been pre-titrated and tested by flow cytometric analysis of normal human peripheral blood cells. This can be used at 5 µL (0.25 µg) per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test.

PerCP-eFluorâ„¢ 710 can be used in place of PE-Cy5, PE-Cy5.5 or PerCP-Cy5.5. PerCP-eFluorâ„¢ 710 emits at 710 nm and is excited with the blue laser (488 nm). Please make sure that your instrument is capable of detecting this fluorochrome. For a filter configuration, we recommend using the 685 LP dichroic mirror and 710/40 band pass filter, however the 695/40 band pass filter is an acceptable alternative.

Our testing indicates that PerCP-eFluor™ 710 conjugated antibodies are stable when stained samples are exposed to freshly prepared 2% formaldehyde overnight at 4°C, but please evaluate for alternative fixation protocols.

Excitation: 488 nm; Emission: 710 nm; Laser: Blue Laser.

Filtration: 0.2 µm post-manufacturing filtered.

 

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
HLA-ABC Monoclonal Antibody (W6/32), PerCP-eFluor 710, eBioscience | Cytek Biosciences