🚚 Free Worldwide Shipping on All Orders!Shop Now
CD49f (Integrin alpha 6) Monoclonal Antibody (eBioGoH3 (GoH3)), Alexa Fluor 700, eBioscience
HomeStore

CD49f (Integrin alpha 6) Monoclonal Antibody (eBioGoH3 (GoH3)), Alexa Fluor 700, eBioscience

CD49f (Integrin alpha 6) Monoclonal Antibody (eBioGoH3 (GoH3)), Alexa Fluor 700, eBioscience

PRODUCT DETAILS

Host: Rat

Isotype: IgG2a, kappa

Clonality: Monoclonal

Clone: eBioGoH3 (GoH3)

Format: Alexa Fluor 700

Reactivity: Hu, Ms

Application: Flow Cytometry

Tested Dilution: 0.25 µg/test

Concentration: 0.2 mg/mL

Storage: 4°C, store in dark, DO NOT FREEZE!

Formulation: PBS with 0.09% sodium azide; pH 7.2

Purification: Affinity chromatography

Data Sheet: TDS


Specific Information

Description: The eBioGoH3 monoclonal antibody reacts with mouse and human CD49f, also known as integrin alpha 6, very late activation antigen 6 (VLA-6 alpha chain), and platelet gpIc. CD49f is a 120 kD transmembrane protein. CD49f associates with CD29, the integrin beta 1 chain, to form the VLA-6 complex; CD49f also associates with CD104, the integrin beta 4 chain, to form the alpha 6 beta 4 complex. CD49f is expressed primarily on T cells, monocytes, platelets, epithelial and endothelial cells. CD49f expression has also been found on germinal center B cells. The eBioGoH3 antibody is cross-reactive to integrin alpha 6 on human, mouse and bovine cells. This antibody has also been reported to have functional activity in blocking the binding of integrin alpha 6 to laminin.

Applications Reported: This eBioGoH3 antibody has been reported for use in flow cytometric analysis.

Applications Tested: This eBioGoH3 antibody has been tested by flow cytometric analysis of normal human peripheral blood cells. This may be used at less than or equal to 0.25 µg per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test. It is recommended that the antibody be carefully titrated for optimal performance in the assay of interest.

Alexa Fluor 700 emits at 723 nm and can be excited with the red laser (633-647 nm). Most instruments will require a 685 LP mirror and 710/20 band pass filter. Please make sure that your instrument is capable of detecting this fluorochrome.

Excitation: 633-647 nm; Emission: 723 nm; Laser: Red Laser

 

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
$128.40

Original: $428.00

-70%
CD49f (Integrin alpha 6) Monoclonal Antibody (eBioGoH3 (GoH3)), Alexa Fluor 700, eBioscience—

$428.00

$128.40

CD49f (Integrin alpha 6) Monoclonal Antibody (eBioGoH3 (GoH3)), Alexa Fluor 700, eBioscience

PRODUCT DETAILS

Host: Rat

Isotype: IgG2a, kappa

Clonality: Monoclonal

Clone: eBioGoH3 (GoH3)

Format: Alexa Fluor 700

Reactivity: Hu, Ms

Application: Flow Cytometry

Tested Dilution: 0.25 µg/test

Concentration: 0.2 mg/mL

Storage: 4°C, store in dark, DO NOT FREEZE!

Formulation: PBS with 0.09% sodium azide; pH 7.2

Purification: Affinity chromatography

Data Sheet: TDS


Specific Information

Description: The eBioGoH3 monoclonal antibody reacts with mouse and human CD49f, also known as integrin alpha 6, very late activation antigen 6 (VLA-6 alpha chain), and platelet gpIc. CD49f is a 120 kD transmembrane protein. CD49f associates with CD29, the integrin beta 1 chain, to form the VLA-6 complex; CD49f also associates with CD104, the integrin beta 4 chain, to form the alpha 6 beta 4 complex. CD49f is expressed primarily on T cells, monocytes, platelets, epithelial and endothelial cells. CD49f expression has also been found on germinal center B cells. The eBioGoH3 antibody is cross-reactive to integrin alpha 6 on human, mouse and bovine cells. This antibody has also been reported to have functional activity in blocking the binding of integrin alpha 6 to laminin.

Applications Reported: This eBioGoH3 antibody has been reported for use in flow cytometric analysis.

Applications Tested: This eBioGoH3 antibody has been tested by flow cytometric analysis of normal human peripheral blood cells. This may be used at less than or equal to 0.25 µg per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test. It is recommended that the antibody be carefully titrated for optimal performance in the assay of interest.

Alexa Fluor 700 emits at 723 nm and can be excited with the red laser (633-647 nm). Most instruments will require a 685 LP mirror and 710/20 band pass filter. Please make sure that your instrument is capable of detecting this fluorochrome.

Excitation: 633-647 nm; Emission: 723 nm; Laser: Red Laser

 

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.

Product Information

Shipping & Returns

Description

PRODUCT DETAILS

Host: Rat

Isotype: IgG2a, kappa

Clonality: Monoclonal

Clone: eBioGoH3 (GoH3)

Format: Alexa Fluor 700

Reactivity: Hu, Ms

Application: Flow Cytometry

Tested Dilution: 0.25 µg/test

Concentration: 0.2 mg/mL

Storage: 4°C, store in dark, DO NOT FREEZE!

Formulation: PBS with 0.09% sodium azide; pH 7.2

Purification: Affinity chromatography

Data Sheet: TDS


Specific Information

Description: The eBioGoH3 monoclonal antibody reacts with mouse and human CD49f, also known as integrin alpha 6, very late activation antigen 6 (VLA-6 alpha chain), and platelet gpIc. CD49f is a 120 kD transmembrane protein. CD49f associates with CD29, the integrin beta 1 chain, to form the VLA-6 complex; CD49f also associates with CD104, the integrin beta 4 chain, to form the alpha 6 beta 4 complex. CD49f is expressed primarily on T cells, monocytes, platelets, epithelial and endothelial cells. CD49f expression has also been found on germinal center B cells. The eBioGoH3 antibody is cross-reactive to integrin alpha 6 on human, mouse and bovine cells. This antibody has also been reported to have functional activity in blocking the binding of integrin alpha 6 to laminin.

Applications Reported: This eBioGoH3 antibody has been reported for use in flow cytometric analysis.

Applications Tested: This eBioGoH3 antibody has been tested by flow cytometric analysis of normal human peripheral blood cells. This may be used at less than or equal to 0.25 µg per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test. It is recommended that the antibody be carefully titrated for optimal performance in the assay of interest.

Alexa Fluor 700 emits at 723 nm and can be excited with the red laser (633-647 nm). Most instruments will require a 685 LP mirror and 710/20 band pass filter. Please make sure that your instrument is capable of detecting this fluorochrome.

Excitation: 633-647 nm; Emission: 723 nm; Laser: Red Laser

 

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
CD49f (Integrin alpha 6) Monoclonal Antibody (eBioGoH3 (GoH3)), Alexa Fluor 700, eBioscience | Cytek Biosciences