🚚 Free Worldwide Shipping on All Orders!Shop Now
CD3e Monoclonal Antibody (145-2C11), NovaFluor Yellow 660, eBioscience
HomeStore

CD3e Monoclonal Antibody (145-2C11), NovaFluor Yellow 660, eBioscience

CD3e Monoclonal Antibody (145-2C11), NovaFluor Yellow 660, eBioscience

PRODUCT DETAILS

Host: Armenian Hamster

Isotype: IgG

Clonality: Monoclonal

Clone: 145-2C11

Format: NovaFluor Yellow 660

Reactivity: Ms

Application: Flow Cytometry

Tested Dilution: 1.0 µg/test

Concentration: 0.1 mg/mL

Storage: 4°C, store in dark, DO NOT FREEZE!

Formulation: PBS with 0.09% sodium azide; pH 7.2

Purification: Affinity chromatography

Data Sheet: TDS


Specific Information

Description: The 145-2C11 monoclonal antibody reacts with mouse CD3e, a 20 kDa subunit of the TCR complex. Along with the other CD3 subunits, gamma and delta, the epsilon chain is required for proper assembly, trafficking and surface expression of the TCR complex. CD3 is expressed by thymocytes in a developmentally regulated manner and by all mature T cells. Binding of 145-2C11 to TCR initiates the intracellular biochemical pathway resulting in cellular activation, proliferation, and apoptosis depending on specific conditions utilized. 145-2C11 is commonly used as a phenotypic marker for mouse T cells.

Each product contains 1 vial of NovaFluor conjugate and 1 vial of CellBlox Plus Blocking Buffer .

Applications Reported: This 145-2c11 antibody has been reported for use in flow cytometric analysis.

Applications Tested: This 145-2c11 antibody has been tested by flow cytometric analysis of mouse splenocytes. This may be used at less than or equal to 1.0 µg per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test. It is recommended that the antibody be carefully titrated for optimal performance in the assay of interest.

NovaFluor dyes are not compatible with DNA intercalating viability dyes. Do not use viability dyes such as propidium iodide, 7-actinomycin D (7-AAD) and DAPI. Invitrogen LIVE/DEAD Fixable Dead Cell stains are recommended for use with NovaFluor dyes.

This NovaFluor conjugate has been updated to ship with CellBlox Plus Blocking Buffer (Cat. No. (C001T06F01)). This buffer contains formulation improvements over CellBlox. CellBlox Plus Blocking Buffer is required for optimal staining with NovaFluor conjugates and should be used in all experiments where NovaFluor conjugates are used. Whenever possible, we recommend adding CellBlox Plus Blocking Buffer to antibody cocktails/master mixes prior to combining with cells. Add 5 µL per sample (regardless of the number of NovaFluors in your panel) to use the antibody cocktail as intended. For single-color controls, use 5 µL of CellBlox Blocking Buffer per 100 µL of cell sample containing 10^3 to 10^8 cells.

NovaFluor conjugates are based on Phitonâ„¢ technology utilizing novel nucleic acid dye structures that allow for engineered fluorescent signatures with consideration for spillover and spread impacts. Learn more

Excitation: 552 nm; Emission: 663 nm; Laser: 561 nm (Yellow) Laser

Our internal testing shows that NovaFluor Yellow 660 non-specifically stains B cells in SJL mice. Non-specific staining has not been observed in BALB/c or C57BL/6 mice. Other strains have not been tested. See the Antibody Testing Data for an example of this strain-dependent difference.

 

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
$62.70

Original: $209.00

-70%
CD3e Monoclonal Antibody (145-2C11), NovaFluor Yellow 660, eBioscience—

$209.00

$62.70

CD3e Monoclonal Antibody (145-2C11), NovaFluor Yellow 660, eBioscience

PRODUCT DETAILS

Host: Armenian Hamster

Isotype: IgG

Clonality: Monoclonal

Clone: 145-2C11

Format: NovaFluor Yellow 660

Reactivity: Ms

Application: Flow Cytometry

Tested Dilution: 1.0 µg/test

Concentration: 0.1 mg/mL

Storage: 4°C, store in dark, DO NOT FREEZE!

Formulation: PBS with 0.09% sodium azide; pH 7.2

Purification: Affinity chromatography

Data Sheet: TDS


Specific Information

Description: The 145-2C11 monoclonal antibody reacts with mouse CD3e, a 20 kDa subunit of the TCR complex. Along with the other CD3 subunits, gamma and delta, the epsilon chain is required for proper assembly, trafficking and surface expression of the TCR complex. CD3 is expressed by thymocytes in a developmentally regulated manner and by all mature T cells. Binding of 145-2C11 to TCR initiates the intracellular biochemical pathway resulting in cellular activation, proliferation, and apoptosis depending on specific conditions utilized. 145-2C11 is commonly used as a phenotypic marker for mouse T cells.

Each product contains 1 vial of NovaFluor conjugate and 1 vial of CellBlox Plus Blocking Buffer .

Applications Reported: This 145-2c11 antibody has been reported for use in flow cytometric analysis.

Applications Tested: This 145-2c11 antibody has been tested by flow cytometric analysis of mouse splenocytes. This may be used at less than or equal to 1.0 µg per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test. It is recommended that the antibody be carefully titrated for optimal performance in the assay of interest.

NovaFluor dyes are not compatible with DNA intercalating viability dyes. Do not use viability dyes such as propidium iodide, 7-actinomycin D (7-AAD) and DAPI. Invitrogen LIVE/DEAD Fixable Dead Cell stains are recommended for use with NovaFluor dyes.

This NovaFluor conjugate has been updated to ship with CellBlox Plus Blocking Buffer (Cat. No. (C001T06F01)). This buffer contains formulation improvements over CellBlox. CellBlox Plus Blocking Buffer is required for optimal staining with NovaFluor conjugates and should be used in all experiments where NovaFluor conjugates are used. Whenever possible, we recommend adding CellBlox Plus Blocking Buffer to antibody cocktails/master mixes prior to combining with cells. Add 5 µL per sample (regardless of the number of NovaFluors in your panel) to use the antibody cocktail as intended. For single-color controls, use 5 µL of CellBlox Blocking Buffer per 100 µL of cell sample containing 10^3 to 10^8 cells.

NovaFluor conjugates are based on Phitonâ„¢ technology utilizing novel nucleic acid dye structures that allow for engineered fluorescent signatures with consideration for spillover and spread impacts. Learn more

Excitation: 552 nm; Emission: 663 nm; Laser: 561 nm (Yellow) Laser

Our internal testing shows that NovaFluor Yellow 660 non-specifically stains B cells in SJL mice. Non-specific staining has not been observed in BALB/c or C57BL/6 mice. Other strains have not been tested. See the Antibody Testing Data for an example of this strain-dependent difference.

 

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.

Product Information

Shipping & Returns

Description

PRODUCT DETAILS

Host: Armenian Hamster

Isotype: IgG

Clonality: Monoclonal

Clone: 145-2C11

Format: NovaFluor Yellow 660

Reactivity: Ms

Application: Flow Cytometry

Tested Dilution: 1.0 µg/test

Concentration: 0.1 mg/mL

Storage: 4°C, store in dark, DO NOT FREEZE!

Formulation: PBS with 0.09% sodium azide; pH 7.2

Purification: Affinity chromatography

Data Sheet: TDS


Specific Information

Description: The 145-2C11 monoclonal antibody reacts with mouse CD3e, a 20 kDa subunit of the TCR complex. Along with the other CD3 subunits, gamma and delta, the epsilon chain is required for proper assembly, trafficking and surface expression of the TCR complex. CD3 is expressed by thymocytes in a developmentally regulated manner and by all mature T cells. Binding of 145-2C11 to TCR initiates the intracellular biochemical pathway resulting in cellular activation, proliferation, and apoptosis depending on specific conditions utilized. 145-2C11 is commonly used as a phenotypic marker for mouse T cells.

Each product contains 1 vial of NovaFluor conjugate and 1 vial of CellBlox Plus Blocking Buffer .

Applications Reported: This 145-2c11 antibody has been reported for use in flow cytometric analysis.

Applications Tested: This 145-2c11 antibody has been tested by flow cytometric analysis of mouse splenocytes. This may be used at less than or equal to 1.0 µg per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test. It is recommended that the antibody be carefully titrated for optimal performance in the assay of interest.

NovaFluor dyes are not compatible with DNA intercalating viability dyes. Do not use viability dyes such as propidium iodide, 7-actinomycin D (7-AAD) and DAPI. Invitrogen LIVE/DEAD Fixable Dead Cell stains are recommended for use with NovaFluor dyes.

This NovaFluor conjugate has been updated to ship with CellBlox Plus Blocking Buffer (Cat. No. (C001T06F01)). This buffer contains formulation improvements over CellBlox. CellBlox Plus Blocking Buffer is required for optimal staining with NovaFluor conjugates and should be used in all experiments where NovaFluor conjugates are used. Whenever possible, we recommend adding CellBlox Plus Blocking Buffer to antibody cocktails/master mixes prior to combining with cells. Add 5 µL per sample (regardless of the number of NovaFluors in your panel) to use the antibody cocktail as intended. For single-color controls, use 5 µL of CellBlox Blocking Buffer per 100 µL of cell sample containing 10^3 to 10^8 cells.

NovaFluor conjugates are based on Phitonâ„¢ technology utilizing novel nucleic acid dye structures that allow for engineered fluorescent signatures with consideration for spillover and spread impacts. Learn more

Excitation: 552 nm; Emission: 663 nm; Laser: 561 nm (Yellow) Laser

Our internal testing shows that NovaFluor Yellow 660 non-specifically stains B cells in SJL mice. Non-specific staining has not been observed in BALB/c or C57BL/6 mice. Other strains have not been tested. See the Antibody Testing Data for an example of this strain-dependent difference.

 

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.

You may also like

NEW
Thumbnail 1

CD135 (Flt3) Monoclonal Antibody (A2F10), PE, eBioscience

$277.00

NEW
Thumbnail 1

CD135 (Flt3) Monoclonal Antibody (BV10A4H2), APC, eBioscience

$383.00

NEW
Thumbnail 1

CD135 (Flt3) Monoclonal Antibody (BV10A4H2), PE, eBioscience

$321.00

NEW
Thumbnail 1

CD134 (OX40) Monoclonal Antibody (OX40), APC, eBioscience

$351.00

NEW
Thumbnail 1

CD134 (OX40) Monoclonal Antibody (OX-86), Super Bright 436, eBioscience

$180.00

NEW
Thumbnail 1

CD134 (OX40) Monoclonal Antibody (OX-86), PerCP-eFluor 710, eBioscience

$524.00

NEW
Thumbnail 1

CD135 (Flt3) Monoclonal Antibody (A2F10), eBioscience

$158.00

NEW
Thumbnail 1

CD135 (Flt3) Monoclonal Antibody (A2F10), APC, eBioscience

$340.00

NEW
Thumbnail 1

CD135 (Flt3) Monoclonal Antibody (A2F10), PE-Cyanine5, eBioscience

$462.00

NEW
Thumbnail 1

CD135 (Flt3) Monoclonal Antibody (A2F10), Biotin, eBioscience

$261.00

NEW
Thumbnail 1

CD135 (Flt3) Monoclonal Antibody (A2F10), PerCP-eFluor 710, eBioscience

$412.00

NEW
Thumbnail 1

CD133 (Prominin-1) Monoclonal Antibody (EMK08), PE-Cyanine7, eBioscience

$478.00